Add to Cart
450/750v Rubber Insulated Cable 2*1.5mm 2.5mm2 4mm2 6mm2 Silicone Rubber Insulated Flexible Power Cable
XLPE insulated power cable has a number of advantages over paper insulated and PVC insulated cable.XLPE power cable has high electric strength, mechanical strength, high-ageing resisting, environment stress resisting anti chemical corrossion, and it is simple construction, using convenient and higher operating of long term temperature. It can be laid with no drop restriction.It is widely used in electric power,construction,mining,metallurgy,petrochemical,transportation etc.
Type | Designation | Core No. | Production Range mm2 | Related voltage V |
RV | General ourpose single core soft conductor cable without sheat | 1 | 1.5-240 | 450/750 |
RV | Inner wiring purpose single core soft conductor cable without sheat 70C for conductor temperature | 1 | 0.5-1.0 | 300/500 |
RVV | Light type PVC sheat soft cable | 2-3 | 0.5-0.75 | 300/300 |
RVV | General PVC sheath soft wire | 2-5 | 0.75-2.5 | 300/500 |
RVVP | Cu conductor PVC insulation sheath and shilded soft cable | 1-24 | 0.5-6 | 300/300 |
The type name and specification of product:
Cross-sectional area(mm) | Number/diameter of core(mm) | Maximum outer diameter(mm) | Reference weight(kg/km) | Conductor resistance at 20℃≤(Ω/km) | ||
copper | alumimum | alumimum | copper | |||
1.5 | 1/1.38 | 3.3 | 20.3 | - | - | 12.1 |
1.5 | 7/0.52 | 3.5 | 21.6 | - | - | 12.1 |
2.5 | 1/1.78 | 3.9 | 31.6 | 17 | 11.8 | 7.41 |
2.5 | 7/0.68 | 4.2 | 34.8 | - | - | 7.41 |
4 | 1/2.55 | 4.4 | 47.1 | 22 | 7.39 | 4.61 |
4 | 7/0.85 | 4.8 | 50.3 | - | - | - |
6 | 7/2.78 | 4.8 | 50.3 | 29 | 4.91 | 3.08 |
6 | 7/1.04 | 5.4 | 71.2 | - | - | 3.08 |
10 | 7/1.35 | 7.0 | 119 | 62 | 3.08 | 1.83 |
16 | 7/1.70 | 8.0 | 179 | 78 | 1.91 | 1.15 |
25 | 7/2.14 | 10.0 | 281 | 118 | 1.20 | 0.727 |
35 | 7/2.52 | 11.5 | 381 | 156 | 0.868 | 0.524 |
50 | 19/1.78 | 13.0 | 521 | 215 | 0.641 | 0.387 |
70 | 19/2.14 | 15.0 | 734 | 282 | 0.443 | 0.268 |
95 | 19/25.2 | 17.5 | 962 | 385 | 0.320 | 0.193 |
120 | 37/2.03 | 19.0 | 1180 | 431 | 0.253 | 0.153 |
150 | 37/2.25 | 21.0 | 1470 | 539 | 0.206 | 0.124 |
185 | 37/2.25 | 23.5 | 1810 | 666 | 0.164 | 0.0991 |
240 | 61/2.25 | 26.5 | 2350 | 857 | 0.125 | 0.0754 |
300 | 61/2.52 | 29.5 | 2930 | 1070 | 0.100 | 0.0601 |
400 | 61/2.85 | 33.0 | 3870 | 1390 | 0.0778 | 0.0470 |
Running conditions:
a. The long-term allowable operating temperature of PVC insulated cable conductors is 70 °C, and the maximum operating temperature of cable conductors is 160 °C when short-circuited (maximum duration does not exceed 5 seconds); the long-term allowable operating temperature of XLPE insulated cable conductors is 90 °C, short-circuit (The maximum duration does not exceed 5S) The maximum operating temperature of the cable conductor is 250 ° C;
b. The long-term allowable working temperature of the cable conductor is 105 °C;
c. Allowable bending radius of the cable: the outer diameter is less than 25mm, the bending radius is not less than 4D; the outer diameter is 25mm and above, and the bending radius is not less than 6D.